| Home | |
|---|---|
| Categories | |
| Product List | |
| Contacts | |
90-day Warranty Parts and Labor | |
| Links: | ||||
| Refurbished Lab and Analytical Equipment | Toll Free 877 831-5580 Phone 510 783-1127 Fax 510 783-1168 info@sci-support.com | ||
|---|---|---|---|
| Equipment Service and Repair |
HPLC Detectors | |||
|---|---|---|---|
| # 1215 | Dionex AD20 (AD 20) Absorbance Detector | ||
|
Dual-beam optical system, fiber-optic beamsplitter and concave holographic diffraction grating Wavelength range 190-800 nm, 1 nm increment Wavelength accuracy ±1, bandwidth 8nm, automatic wavelength calibration. Absorbance range 0-2 AU | ||
| Price: $3600 | Email for more info | Call 877 831-5580 | |
| # 1362 | Dionex AD25 Absorbance Detector | ||
|
Wavelength range: 190 nm to 800 nm in 1nm step Wavelength accuracy ± 1 nm Bandwidth less than 5 nm Analog output range 0.001, 0.005, 0.01, 0.05, 0.1, 0.5, 1.0, 2.0, and 3.0 AU Flow cell: PEEK 10 µl volume; 10 mm (0.394 in) optical path length | ||
| Price: $4900 | Email for more info | Call 877 831-5580 | |
| # 1368 | Dionex CD20 (CD-20) Conductivity Detector | ||
|
Range: 0.01 mS to 3000 mS, full scale (Conductivity) Cell Drive - Variable 8 kHz square wave Temperature Compensation - 0.0 to 3.0% per °C | ||
| Price: $3800 | Email for more info | Call 877 831-5580 | |
| # 1219 | Dionex ED40 (ED-40) Electrochemical Detector | ||
|
Conductivity, DC amperometry, and integrated amperometry modes Range: 0.01 mS to 3000 mS, full scale (Conductivity), 50 pA to 300 mA (DC Amperometry) Range: 50 pC to 200 mC (Integrated Amperometry) Temperature Compensation - 0.0 to 3.0% per °C (Conductivity) Cell Drive - Variable 8 kHz square wave (Conductivity) ; 2.04 V (DC and Integrated Amperometry) | ||
| Price: $4200 | Email for more info | Call 877 831-5580 | |
| # 1370 | Dionex ED50 (ED-50) Electrochemical Detector | ||
|
Conductivity, DC amperometry, and integrated amperometry modes Range: 0.01 mS to 3000 mS, full scale (Conductivity), 50 pA to 300 mA (DC Amperometry) Range: 50 pC to 200 mC (Integrated Amperometry) Temperature Compensation - 0.0 to 3.0% per °C (Conductivity) Cell Drive - Variable 8 kHz square wave (Conductivity) ; 2.04 V (DC and Integrated Amperometry) | ||
| Price: $5200 | Email for more info | Call 877 831-5580 | |
| # 1081 | Hewlett-Packard HP 1046A Fluorescence Detector | ||
|
Light source: Xenon flash, pulsed at 55- 220 Hz Excitation: Wavelength range190-800 nm, Bandwidth - 12, 25, 50 nm Emission: Wavelength range190-800 nm, Bandwidth - 12, 25, 50, 140 nm HP-IB and analog outputs | ||
| Price: $4600 | Email for more info | Call 877 831-5580 | |
| # 1184 | Hewlett-Packard HP 1047A Refractive Index Detector | ||
|
Refractive Index range 1.00-1.75 Measurement range 1/64x10-5 delta RIU to 32x10-5 delta RIU Response time: 0.3, 0.8 or 5 seconds (10 to 90%). Flow cell volume 7 ul volume with 7 bar (103 psi) maximum pressure. Flow cell maximum pressure 7 bar (103 psi) Temperature control: 30°C,35°C,40°C,45°,50°C. | ||
| Price: $3600 | Email for more info | Call 877 831-5580 | |
| # 1486 | Linear UVIS-205 Absorbance Detector | ||
|
Wavelength range 190-800 nm, 1 nm increment Wavelength accuracy ±1nm, bandwidth 6nm Wavelength precision: ±0.1nm Absorbance range: 0.0005 to 3.0 AUFS Range selection: 3.0,2.0, 1.0,0.5,0.2,0.1,0.05,0.02,0.01,0.005,0.002,0.001,0.0005 AUFS | ||
| Price: $2500 | Email for more info | Call 877 831-5580 | |
| # 1391 | Thermo Separation Products UV2000 SpectraSystem | ||
|
Variable dual wavelength detector Wavelength range: 190 nm to 800 nm in 1nm step Wavelength accuracy ± 1 nm Bandwidth: less than 6 nm Absorbance range: 0.0005 to 3 AUFS | ||
| Price: $2400 | Email for more info | Call 877 831-5580 | |
| # 1181 | Waters 410 Refractive Index Detector | ||
|
Refractive index range: 1.00-1.75 Cell volume: 10 ul , cell pressure (maximum): 100 psi Flow rate: 0.3 - 10.0 ml/min Auto zero and cell purge functions Temperature-controlled optics, temperature limit alarm | ||
| Price: $3600 | Email for more info | Call 877 831-5580 | |
| # 1222 | Waters 486 Tunable Absorbance Detector | ||
|
Wavelength range of 190-600 nm Accuracy - 2 nm Repeatability - 2 nm | ||
| Price: $3500 | Email for more info | Call 877 831-5580 | |
| # 1251 | Waters 994 Programmable Photodiode Array Detector | ||
|
Wavelength range 190-780 nm Band width 2-20 nm or full Measurement time 1-91.7 min Four-channel signal output Printer/plotter output | ||
| Price: $4800 | Email for more info | Call 877 831-5580 | |
| # 1295 | Waters M-470 Scanning Fluorescence Detector | ||
|
| ||
| Price: $3600 | Email for more info | Call 877 831-5580 | |
| # 1050 | Hewlett-Packard HP 1049A Programmable Electrochemical Detector | ||
|
Includes electrochemical cell and optional solvent thermostat. Gold working electrode, reference electrode with internal electrolyte. HP-IB interface., analog output, Remote connector | ||
| Price: Sold | Email for more info | Call 877 831-5580 | |
Copyright © 2008 Scientific Support, Inc. All rights reserved |
All Registered Trademarks are the property of their respective owners. |
| Last Updated : 6/10/2008 |